In electronics and signal processing, full scale represents the maximum amplitude a system can represent.

In digital systems, a signal is said to be at digital full scale when its magnitude has reached the maximum representable value. Once a signal has reached digital full scale, all headroom has been utilized, and any further increase in amplitude will result in an error known as clipping. The amplitude of a digital signal can be represented in percent; full scale; or decibels, full scale (dBFS).

In analog systems, full scale may be defined by the maximum voltage available, or the maximum deflection (full scale deflection or FSD) or indication of an analog instrument such as a moving coil meter or galvanometer.

Binary representation

edit

Since binary integer representation range is asymmetrical, full scale is defined using the maximum positive value that can be represented.[1][2] For example, 16-bit PCM audio is centered on the value 0, and can contain values from −32,768 to +32,767. A signal is at full-scale if it reaches from −32,767 to +32,767. (This means that −32,768, the lowest possible value, slightly exceeds full-scale.)

Signal processing in digital audio workstations often uses floating-point arithmetic, which can include values past full-scale, to avoid clipping in intermediate processing stages. In a floating-point representation, a full-scale signal is typically defined to reach from −1.0 to +1.0.[3][4]

Processing

edit

The signal passes through an anti-aliasing, resampling, or reconstruction filter, which may increase peak amplitude slightly due to ringing.

It is possible for the analog signal represented by the digital data to exceed digital full scale even if the digital data does not, and vice versa. Converting to the analog domain, there is no clipping problem as long as the analog circuitry in the digital-to-analog converter is well designed.

If a full-scale analog signal is converted to digital with sufficient sampling frequency, and then reconstructed, the Nyquist theorem guarantees that there will be no problem in the analog domain due to "peak" issues because the restored analog signal will be an exact copy of the original analog signal. (However, if the signal is normalized in the digital domain, it may contain "intersample peaks" which exceed full scale after analog reconstruction.)[5]

References

edit
  1. ^ "AES Standard » AES17-2015: AES standard method for digital audio engineering - Measurement of digital audio equipment". www.aes.org. Retrieved 2016-04-29. amplitude of a 997-Hz sine wave whose positive peak value reaches the positive digital full scale, leaving the negative maximum code unused. NOTE In 2's-complement representation, the negative peak is 1 LSB away from the negative maximum code.
  2. ^ "IEC 61606-3:2008 Audio and audiovisual equipment - Digital audio parts - Basic measurement methods of audio characteristics - Part 3: Professional use". International Electrotechnical Commission. 2008. Retrieved 2018-07-27. amplitude of a 997 Hz sinusoid whose peak positive sample just reaches positive digital full-scale (in 2's-complement a binary value of 0111…1111 to make up the word length) and whose peak negative sample just reaches a value one away from negative digital full-scale (1000…0001 to make up the word length) leaving the maximum negative code (1000…0000) unused
  3. ^ "Wave File Specifications". McGill University Telecommunications & Signal Processing Laboratory. Retrieved 2020-05-03. For float data, full scale is 1.
  4. ^ "Adobe Audition User Guide" (PDF). 32-bit 0.24 normalized float (type 3 – 32-bit) is the standard floating point format for type 3 .wav files. Values are normalized to the range +/-1.0
  5. ^ Nielsen, Søren H.; Lund, Thomas. "0dBFS+ Levels in Digital Mastering" (PDF). TC Electronic A/S. Denmark. Archived from the original (PDF) on 2019-05-02. Retrieved 2018-07-27.

📚 Artikel Terkait di Wikipedia

Multimeter

basic full-scale deflection current of the movement, and the sum of the series resistance and the movement's own resistance, gives the full-scale voltage

Full Scale (band)

Full Scale (formerly known as Full Scale Deflection, later known as Full Scale Revolution) is an Australian alternative metal band that formed in Perth

Difference in the depth of modulation

is 15.5% or an electric current equivalent of 150 microamperes full scale deflection. A modulation depth comparison navigational aid (MDCNA), also known

Ammeter

the deflection of the meter linearly proportional to current. These meters have linear scales. Basic meter movements can have full-scale deflection for

Galvanometer

adjusted to produce full-scale deflection. When an unknown resistor is placed in series in the circuit the current will be less than full scale and an appropriately

FSD

Fourteen-segment display Flame supervision device Full-stack developer Free Shipping Day Full scale deflection, the maximum amount the pointer of an analog

Avometer

mA for full-scale deflection and used a "universal shunt" permanently in parallel with the movement which increased the input terminal full-scale current

AUFS